Date Confirmed: 03-30-98

PCM Status: CONFIRMED

PC Manufacturer: DELL COMPUTER CORP

Model: DELL POWEREDGE 6100/200 2-CPU

System Type: SERVER

Equivalent Models: NONE

Testkit Version: V4.1

OS/2 Product Tested: OS/2 WARP SERVER ADVANCED SMP V4

OS/2 FixPacks Applied: NOT PROVIDED

Test results received by the IBM OS2 Compatiblity Program Office for the system model above showed
All Tests Pass for OS/2 Hardware Compatibility Testkit Version V4.1. This system model, as tested by
the Manufacturer and identified in the Machine Configuration file (machine.txt) submitted by the
Manufacturer, is hereby added to the OS/2 Hardware Compatibility List on the Web. Please allow ten
days for posting (www.software.ibm.com/os/warp/hw-cert/pcm/pcm_syst.htm).

Pursuant to the terms of the OS/2 Compatibility Testkit License Agreement, IBM discloses the Test
Report attached. A signed original of the OS/2 Tested and Approved for LAN Systems Logo License
Agreement must be submitted to the OS/2 Compatibility Program Office for use of the logo by the
Manufacturer in any product promotions. For questions regarding these test results or the compatibility
of systems or model configurations not provided herein, contact the Manufacturer per information
provided in the attached Test Report.





















(Original filed at IBM Austin Texas, Server AUSDB006\OEM\PCMTABLE.NSF, Cert# EA5C3B9C277FF677862565D4005402AF)


Test Report

___________________________________________________________________________________


OS/2 Compatibility Test Results Summary (pcmscore.txt):


PCM Base Test________SNF001_____________PASS
PCM Base Test________SNF002_____________PASS
PCM Base Test________SNF006_____________PASS
PCM Base Test________SNF007_____________PASS
PCM Base Test________SNFBPB_____________PASS
PCM Base Test________SNFREXX____________PASS
PCM Base Test________SNFMVDM____________PASS
PCM Base Test________SNFWIN_____________PASS
PCM Base Test________STRESS_____________PASS
PCM Base Test________KBD________________PASS
PCM Base Test________FVTDISK____________PASS
PCM Base Test________FORMAT_____________PASS
PCM Base Test________TIMERDD____________PASS
PCM Base Test________PRINTDD____________PASS
PCM Base Test________MMPM2______________PASS
PCM Base Test________APM________________NOT RUN
PCM Base Test________PCMCIA_____________NOT RUN
PCM Base Test________SMP________________PASS
.
PCM LAN Domain_______ITLLS56.S01________PASS
PCM LAN Domain_______ITLLS56.R01________PASS
PCM LAN Domain_______ITLLS56.R02________PASS
PCM LAN Domain_______ITLMSG.D01_________PASS
PCM LAN Domain_______ITLMSG.R01_________PASS
PCM LAN Domain_______ITLFTP02.R02_______PASS
PCM LAN Domain_______ITLTCP01.D01_______PASS
PCM LAN Domain_______ITLDUMP.D01________PASS
PCM LAN Domain_______ITLPSNS.D01________PASS
PCM LAN Domain_______ITLRAID.D01________NOT RUN
.
PCM LAN Server_______ITLLS57.D01________PASS
PCM LAN Server_______ITLLS57.R01________PASS
PCM LAN Server_______ITLLS57.R02________PASS
PCM LAN Server_______ITLFTP01.R01_______PASS
PCM LAN Server_______ITLALERT.S01_______PASS
PCM LAN Server_______ITLLD.R02__________PASS
PCM LAN Server_______SYSINFO.RPT________PASS
PCM LAN Server_______IT01D01.HST________PASS
PCM LAN Server_______IT01D01.INV________PASS
PCM LAN Server_______IT01S01.HST________PASS
PCM LAN Server_______IT01S01.INV________PASS
PCM LAN Server_______IT01R01.HST________PASS
PCM LAN Server_______IT01R01.INV________PASS
PCM LAN Server_______IT01R02.HST________PASS
PCM LAN Server_______IT01R02.INV________PASS
PCM LAN Server_______ITLPSF00.S01_______PASS
PCM LAN Server_______ITLSV06.S01________PASS


Additional Configuration Information:

1) The 2 Intel Pentium Pro CPU's have 1MB cache each instead of the standard 512KB.
2) In CMOS/EISA the MP Spec was set to 1.4
3) All SCSI 9GB hard drives were configured on the Dell PERC; 3 drives for RAID 5.
4) The Primary embedded SCSI controler was turned off.
5) The 12/24 SCSI CDROM was connected to the Secondary embedded SCSI controler.
6) The Intel Pro100B PCI Ethernet driver for OS/2 came from Intel diskette version 2.4
7) All LMS*.* and SONY*.* IDE drivers/filters were removed from the install diskettes.
8) Video choice was Super VGA for 640 by 480 resolution instead of auto detect.
9) Basedev drivers added were pedge.add version 1.07 for the Dell PERC dated 5-13-97 (BIOS 1.44, Firmware U.75) and AIC7870.ADD dated 8-14-96.
10) OS/2 Warp Server Advanced Version 4.0 SMP was used for both roles as Domain Controler and for Additional Server using Ethernet networking; this was syslevel 3.02.
11) MPTS-SMP WO8504 fixpak was applied on top of OS/2 in both roles due to instability with Ethernet connections.

Special OS/2 utilities in binary form are distributed by Dell to manage the Dell PERC controler: dellconf.exe
for local array maintenance, monitor.cmd to start pedgemon.exe. The pedgemon.exe program shows drive state changes and rebuild progress on the loacl OS/2 display monitor. For RAID testing, since IPSRAID was not applicable and since Netfinity Alerts were not logged for this RAID card this procedure was used: monitor.cmd kicked off the pedgemon.exe, the bottom drive of the 3 SCSI drives in the RAID 5 array was removed while the OS was running, then reinserted. The pedgemon.exe showed drive state changes properly and then reuild progress to completion and the system was then successfully rebooted on the rebuilt array.

Machine Configuration (machine.txt):


System Manufacturer___________Dell Computer Corporation
System Model Name_____________PowerEdge 6100/200 2-CPU
Processor-Mhz_________________200Mhz Pentium Pro
Processor on__________________Planar
BUS Type______________________EISA
LocalBUS Type_________________PCI
Symetric Multi-Processor______YES
Number of Processors__________2
.PSD Filename_________________OS2APIC.PSD
Bios Manufacturer_____________Dell
BIOS Version__________________A06
BIOS Date_____________________
Installed Memory MB___________128MB
APM Support___________________NO
PCMCIA Support________________NO
Number PCMCIA Slots___________
MOUSE Mini-Serial-Other_______Mini-Din
MOUSE Other type______________
Video Chip Manufacturer_______Cirrus
Video Chip Model______________CL-GD5424
Video Memory Size_____________1MB
Video Chip on_________________Video on Planar
Video Card Manufacturer_______
Video Card Model______________
Video Card Type_______________
CDROM Drive___________________YES
CDROM Regular_________________Regular
CDROM Streaming able__________
CDROM Drive Manufacturer______NEC
CDROM Drive Model_____________CDR-1810A 12/24
CDROM Connected to____________SCSI
Other connection type_________
Sound Support_________________NO
Sound Card Manufacturer_______
Sound Card Model______________
Disk Controller 1 Mfr_________Dell
Disk Controller 1 Model_______PowerEdge Expandable RAID Controler (PERC)
Disk Controller 1 on__________PCI Card
Disk Controller 2 Mfr_________Adaptec
Disk Controller 2 Model_______AIC 7880UW
Disk Controller 2 on__________Planar
Disk Drive 1 Mfr______________Seagate
Disk Drive 1 Model____________ST19171W
Disk Drive 1 Size_____________9GB
Disk Drive 1 Number installed_3
Disk Drive 1 type_____________SCSI
Disk Drive 2 Mfr______________
Disk Drive 2 Model____________
Disk Drive 2 Size_____________
Disk Drive 2 Number installed_
Disk Drive 2 type_____________
Disk Drive 3 Mfr______________
Disk Drive 3 Model____________
Disk Drive 3 Size_____________
Disk Drive 3 Number installed_
Disk Drive 3 type_____________
Network Card 1 Manufacturer___Intel
Network Card 1 Model/Name_____Pro100B
Network Card 1 is_____________Ethernet
Network Card 1 type___________PCI Card
Network Card 1 .NIF Name______E100BEO2.NIF
Network Card 1 .NIF Date______02-21-97
Network Card 1 .OS2 Name______E100B.OS2
Network Card 1 .OS2 Date______02-21-97
Network Card 1 Driver From____Other
Network Card 2 Manufacturer___
Network Card 2 Model/Name_____
Network Card 2 is_____________
Network Card 2 type___________
Network Card 2 .NIF Name______
Network Card 2 .NIF Date______
Network Card 2 .OS2 Name______
Network Card 2 .OS2 Date______
Network Card 2 Driver From____Other



Manufacturer Contact Information

___________________________________________________________________________________


Dell Server Support, 1-800-967-1068