Date Confirmed: 12-09-98

PCM Status: CONFIRMED

PC Manufacturer: DELL COMPUTER CORP

Model: DELL POWEREDGE 2300/400 WITH PERC 2/SC

System Type: SERVER

Equivalent Models: NONE

Testkit Version: V4.1

OS/2 Product Tested: OS/2 WARP SERVER ADVANCED V4

OS/2 FixPacks Applied: NOT PROVIDED

Test results received by the IBM OS2 Compatiblity Program Office for the system model above showed
All Tests Pass for OS/2 Hardware Compatibility Testkit Version V4.1. This system model, as tested by
the Manufacturer and identified in the Machine Configuration file (machine.txt) submitted by the
Manufacturer, is hereby added to the OS/2 Hardware Compatibility List on the Web. Please allow ten
days for posting (www.software.ibm.com/os/warp/hw-cert/pcm/pcm_syst.htm).

Pursuant to the terms of the OS/2 Compatibility Testkit License Agreement, IBM discloses the Test
Report attached. A signed original of the OS/2 Tested and Approved for LAN Systems Logo License
Agreement must be submitted to the OS/2 Compatibility Program Office for use of the logo by the
Manufacturer in any product promotions. For questions regarding these test results or the compatibility
of systems or model configurations not provided herein, contact the Manufacturer per information
provided in the attached Test Report.





















(Original filed at IBM Austin Texas, Server AUSDB006\OEM\PCMTABLE.NSF, Cert# BED4121643C92AB5422566D5003005AC)


Test Report

___________________________________________________________________________________


OS/2 Compatibility Test Results Summary (pcmscore.txt):


PCM Base Test________SNF001_____________PASS
PCM Base Test________SNF002_____________PASS
PCM Base Test________SNF006_____________PASS
PCM Base Test________SNF007_____________PASS
PCM Base Test________SNFBPB_____________PASS
PCM Base Test________SNFREXX____________PASS
PCM Base Test________SNFMVDM____________PASS
PCM Base Test________SNFWIN_____________PASS
PCM Base Test________STRESS_____________PASS
PCM Base Test________KBD________________PASS
PCM Base Test________FVTDISK____________PASS
PCM Base Test________FORMAT_____________PASS
PCM Base Test________TIMERDD____________PASS
PCM Base Test________PRINTDD____________PASS
PCM Base Test________MMPM2______________PASS
PCM Base Test________APM________________NOT RUN
PCM Base Test________PCMCIA_____________NOT RUN
PCM Base Test________SMP________________NOT RUN
.
PCM LAN Domain_______ITLLS56.S01________PASS
PCM LAN Domain_______ITLLS56.R01________PASS
PCM LAN Domain_______ITLLS56.R02________PASS
PCM LAN Domain_______ITLMSG.D01_________PASS
PCM LAN Domain_______ITLMSG.R01_________PASS
PCM LAN Domain_______ITLFTP02.R02_______PASS
PCM LAN Domain_______ITLTCP01.D01_______PASS
PCM LAN Domain_______ITLDUMP.D01________PASS
PCM LAN Domain_______ITLPSNS.D01________PASS
PCM LAN Domain_______ITLRAID.D01________NOT RUN
.
PCM LAN Server_______ITLLS57.D01________PASS
PCM LAN Server_______ITLLS57.R01________PASS
PCM LAN Server_______ITLLS57.R02________PASS
PCM LAN Server_______ITLFTP01.R01_______PASS
PCM LAN Server_______ITLALERT.S01_______PASS
PCM LAN Server_______ITLLD.R02__________PASS
PCM LAN Server_______SYSINFO.RPT________PASS
PCM LAN Server_______IT01D01.HST________PASS
PCM LAN Server_______IT01D01.INV________PASS
PCM LAN Server_______IT01S01.HST________PASS
PCM LAN Server_______IT01S01.INV________PASS
PCM LAN Server_______IT01R01.HST________PASS
PCM LAN Server_______IT01R01.INV________PASS
PCM LAN Server_______IT01R02.HST________PASS
PCM LAN Server_______IT01R02.INV________PASS
PCM LAN Server_______ITLPSF00.S01_______PASS
PCM LAN Server_______ITLSV06.S01________PASS


Additional Configuration Information:

*NOTE*
SINGLE channel Dell PowerEdge RAID Controler 2/SC (PERC 2/SC) uses PEDGE2SC.ADD. Do not use the DUAL channel RAID Dell PERC driver named PEDGE.ADD.
1) Required: PERC 2/SC placed in one of top 4 PCI BUS Slots to be in PRIMARY PCI BUS
2) RAID 5 was three physical drives at 64K stripes; Read Policy WRTHRU, Write Policy ADAPTIVE, Cache Policy DirectIO; Controler set to FlexRAID Powerfail to ENABLED
3) PCI card placement: Intel Pro100+ at top slot in PCI-1, PERC 2/SC in 4th in PCI-4
4) CMOS- Changed serial ports from AUTO to COM1 and COM2 respectively; turned Primary onboard PCI SCSI OFF; booted from slot devices High to Low but not required; after CMOS changed, rebooted directly to review resource use in Resource Configuration Utility (RCU)
5) Verified in RCU no interrupt sharing between PERC 2/SC, NIC, and secondary onboard PCI SCSI; saved and turned power off as it was counting memory; (changes to RCU require a cold-boot)
6) On 2nd install diskette, changed SCSI drivers to use those from FixPak 35. Because PCI BUS is 3 times faster than older systems, the OS/2 CD's drivers are out of date; new ones are required to enable CDROM data transfers to copy all files and copy correctly to hard drive: OS2DASD.DMD, AIC7870.ADD, OS2CDROM.DMD, CDFS.IFS and OS2SCSI.DMD; during installation, verified those same drivers used when rebooting to hard drive by making sure they were copied to both C:\ and C:\OS2\BOOT; corrected again AFTER install completed since old SCSI drivers were copied to both areas during multiple reboots
7) Chose SuperVGA for video; would normally accept NIC driver choice and change later, but on probing it made no choice; chose 3COM driver during install phase; once install done, added Intel NIC driver into MPTS and then changed NIC to Intel Pro100+; ran shutdown, booted from hard drive; Intel driver diskette is labeled version 2.55 from www.intel.com (actual NIC driver version is 3.1)
8) Once OS/LAN Server connections tested: Added FixPak- FP 38; tested warm/cold boot
9) Next added FixPak- MPTS WO8610 and tested warm/cold boot
10) Installed M64OS2.ZIP ATI driver after all FixPaks; set video to 1024 by 768 by 64K colors; this ATI OS/2 video driver is available from Dell Server Support
11) PERC 2/SC is an entry level single channel RAID PCI controller; it does not have alerting via the dual channel PERC's PEDGEMON.EXE although that does appear to work; the OS/2 array manager program to use with this entry level RAID controller is different from the PERC and is named PEDGE2SC.EXE
12) The Dell PERC 2/SC is not picked up by the OS/2 Cert utility. The Dell PERC 2/SC was tested for RAID 5 rebuild and reboot by pulling one drive out while doing disk activity; the drive was then re-inserted after the alarm sounded from the controller (Yes, PEDGEMON declared a failure also); the PEDGE2SC.EXE array utility was run to check drive status and the drive was labeled FAIL just as PEDGEMON had declared; the utility was used to silence the alarm and to manually start a rebuild; rebuild completed and the system was then warm and cold booted to test RAID 5 recovery which worked with no errors. The PERC 2/SC driver and OS/2 array manager program will be included inside PERC2SC.ZIP and can be obtained at www.dell.com in the "File Library" area. The bottom drive was failed for Domain Controller testing; the middle drive was failed during Additional Server testing.

Machine Configuration (machine.txt):


System Manufacturer___________DELL COMPUTER CORPORATION
System Model Name_____________DELL POWEREDGE 2300/400 with PERC 2/SC
Processor-Mhz_________________400
Processor on__________________Planar
BUS Type______________________ISA
LocalBUS Type_________________PCI
Symetric Multi-Processor______NO
Number of Processors__________1
.PSD Filename_________________
Bios Manufacturer_____________Dell
BIOS Version__________________A04
BIOS Date_____________________
Installed Memory MB___________256MB
APM Support___________________NO
PCMCIA Support________________NO
Number PCMCIA Slots___________
MOUSE Mini-Serial-Other_______Mini-Din
MOUSE Other type______________
Video Chip Manufacturer_______ATI
Video Chip Model______________3D RAGE PRO AGP
Video Memory Size_____________2MB
Video Chip on_________________Video on Planar
Video Card Manufacturer_______
Video Card Model______________
Video Card Type_______________
CDROM Drive___________________YES
CDROM Regular_________________Regular
CDROM Streaming able__________
CDROM Drive Manufacturer______NEC
CDROM Drive Model_____________CDR-1810A 12/24 (464)
CDROM Connected to____________SCSI
Other connection type_________
Sound Support_________________NO
Sound Card Manufacturer_______
Sound Card Model______________
Disk Controller 1 Mfr_________Dell
Disk Controller 1 Model_______Single Channel RAID PERC 2/SC
Disk Controller 1 on__________PCI Card
Disk Controller 2 Mfr_________Adaptec
Disk Controller 2 Model_______AIC-7860 (Secondary onboard PCI SCSI)
Disk Controller 2 on__________Planar
Disk Drive 1 Mfr______________Seagate
Disk Drive 1 Model____________ST39173LC, Rev 5702
Disk Drive 1 Size_____________8.682GB
Disk Drive 1 Number installed_3
Disk Drive 1 type_____________SCSI
Disk Drive 2 Mfr______________
Disk Drive 2 Model____________
Disk Drive 2 Size_____________
Disk Drive 2 Number installed_
Disk Drive 2 type_____________
Disk Drive 3 Mfr______________
Disk Drive 3 Model____________
Disk Drive 3 Size_____________
Disk Drive 3 Number installed_
Disk Drive 3 type_____________
Network Card 1 Manufacturer___Intel
Network Card 1 Model/Name_____Pro100+
Network Card 1 is_____________Ethernet
Network Card 1 type___________PCI Card
Network Card 1 .NIF Name______E100BEO2.NIF
Network Card 1 .NIF Date______11-11-97
Network Card 1 .OS2 Name______E100B.OS2
Network Card 1 .OS2 Date______05-15-98
Network Card 1 Driver From____Other
Network Card 2 Manufacturer___
Network Card 2 Model/Name_____
Network Card 2 is_____________
Network Card 2 type___________
Network Card 2 .NIF Name______
Network Card 2 .NIF Date______
Network Card 2 .OS2 Name______
Network Card 2 .OS2 Date______
Network Card 2 Driver From____



Manufacturer Contact Information

___________________________________________________________________________________


Dell Server Support, 1-800-967-1068