Readme for Corrective Service Facility 2-B Version 1.41 **************************** NOTE: Change bars (|) included to the left of the text indicate that this line has changed or been added since the last READ.ME update. | This readme file describes the features available with Version 1.41 of the Corrective Service Facility (referred to in this document as the FixTool). Once you use this version of the FixTool to service a product, you will not be able to use Version 1.37B or earlier. SYSLEVEL files are modified by FixTool 1.38 and later, causing FixTool 1.37B or earlier not to find products to service. This document supplements the information given in the README.INF that comes with the FixTool. The README.INF includes more details about the FixTool process. CONTENTS: Section 1. How to Use the FixTool EXE (Zip) File Section 2. Files Included in the FixTool EXE File Section 3. How to Tell What FixTool Version You Have Section 4. Basic Installation for First-Time FixPak Users Section 5. Other Ways to Apply Service Section 6. How to Set Up the FixTool for Remote Installation Section 7. How to Customize the Response File Section 8. How to Turn Off Archiving for a FixPak Section 9. Setting Environment Variables Section 10. If You Have a Problem Section 11. Common Error Messages Section 12. Other Known Problems Section 13. List of Changes Made for Each Version (1.38 and Later) ****************************************************************************** Section 1. How to Use the FixTool EXE (Zip) File First, unzip the FixTool zip file onto a diskette or into a directory. You can do this by copying the self-extracting zip file into a new subdirectory and then use the following commands from an OS/2 command prompt: : cd | CSx141 where is the drive that you've put the FixTool zip file on, is the directory that you've copied the self-extracting zip file to. x Country code, where '_' is the US country code. Other NLV country codes are identical to the Country code used in FixPak's. is the fully qualified path where the file is to be unzipped to. If is not a diskette, you can also copy all the files in | onto a diskette, except for CSx141.EXE if you wish. Next, you need OS/2 boot capability. For this, you can use any of the following: - boot the install diskettes for the product you're servicing - create utility diskettes from your system and boot these - use a maintenance partition if you have one - boot through Alt-F1 and go to the command prompt - boot OS/2 as usual and then open an OS/2 session ****************************************************************************** Section 2. Files Included in the FixTool EXE File The following files are included in the FixTool EXE (Zip) file: File Use -------------- ----------------------------------------------------------- BUILD.LVL Contains build information for this FixTool release. CSFPANS.DLL Used by FSERVICE | SERVICE.EXE Executable for applying service through a windowed session SERVICE.HLP SERVICE help file SHPIINST.DLL FixTool required DLL UNPACK.EXE Used to unpack files being serviced UNPACK2.EXE Used to unpack files being serviced VIOCALLS.DLL FixTool required DLL | FSERVICE.EXE Executable for applying service through a command line (used with a response file). IBMCSFLK.DLL Locked file device driver file IBMCSFLK.EXE Locked file device driver file IBMCSFLK.SYS Locked file device driver file IBMCSFLK.MSG Locked file device driver file PACK.EXE Used to pack files being archived or backed up README.INF General Installation instructions for the FixTool RESPONSE.LAN Response file for servicing network-related products | RESPONSE.WP3 Response file for servicing OS/2 Warp v3 base | RESPONSE.WP4 Response file for servicing OS/2 Warp v4 base FSERVICE.MSG FSERVICE message file FPINST.CMD Command file for applying service through FSERVICE (uses standard response files for OS/2 Warp 3, OS/2 Warp 4, and network-related FixPaks) NLS.DLL FixTool required DLL MSG.DLL FixTool required DLL | FILEFIX.DLL FixTool required DLL ARCHCTL.CMD Command file that allows you to turn off archiving for a particular FixPak. | READ.ME This file ****************************************************************************** Section 3. How to Tell What FixTool Version You Have | You can tell if you have Version 1.41 by running BLDLEVEL on SERVICE.EXE or FSERVICE.EXE. You will see one of the following, depending on which version of BLDLEVEL.EXE you have. | Signature: @#IBM:F.141#@ OS/2 Corrective Service Facility (C) IBM 1994 Vendor: IBM | Revision: 0.141 | File Version: 0.141 Description: OS/2 Corrective Service Facility (C) IBM 1994 | Signature: @#IBM:F.141#@ OS/2 Corrective Service Facility (C) IBM 1994 Vendor: IBM | Revision: F.141 Description: OS/2 Corrective Service Facility (C) IBM 1994 The new version of the FixTool (Corrective Service Facility) updates the current CSD field in the SYSLEVEL files of the products it services. After | applying a FixPak with Version 1.41, you will be able to run SYSLEVEL and tell what FixPaks you have applied by looking at the current field of the product's SYSLEVEL file. This version is also compatible with Software Choice features. If you need to use Software Choice to install new features for a product, the FixTool will integrate SYSLEVEL and archive information from the Software Choice install the next time it services that product. ****************************************************************************** |Section 4. Basic Installation for First-Time FixPak Users | | This is a very basic set of instructions to help you install an OS/2 Warp | FixPak; it contains installation tips from OS/2 support technicians. | | This document is designed to help you understand how to prepare your system | and then install an OS/2 Warp base FixPak. It is important that you also read | the README file supplied with the FixPak you are installing. | | This document only discusses local FixPak installations from diskettes using | the Corrective Service Facility (CSF) FixTool 1.41. For other methods of | installation see Section 5. | | Before you can begin the FixPak installation, either obtain the FixPak | diskettes from IBM, or download the FixPak and run LOADDSKF.EXE to convert | the downloaded FixPak images into a usable diskette format. | | Note: LOADDSKF.EXE can be found on the OS/2 Warp installation CD in the | DISKIMGS directory. | |4.1. Prerequisites: | |4.1.1. You must have at least 70 megabytes of free space available on your | hard drive. At least 20 MB of the 70 MB must be available on the C: | drive if installing to another partition. | | To determine how much free space is available, open an OS/2 Command | Prompt window and type CHKDSK; then press Enter. CHKDSK will search | the disk and report its findings, including the number of kilobytes | available for use. This number must exceed 70000 kilobytes. | |4.2.2. You must create utility diskettes. | | These diskettes will allow you to boot to a command prompt and perform | various utility maintenance jobs on your computer to prepare it for the | FixPak install as well as to help recover from some minor problems. | | 4.2.2.1. How to create utility diskettes: | | Note: Before you begin, you must have three blank diskettes and the | installation CD for OS/2 Warp 3 or Warp Server, or four blank diskettes | and the installation CD for OS/2 Warp 4. | | a. From the desktop, click on the OS/2 System icon, | b. Click on the System Setup icon, | c. Click on the Create Utility Diskettes icon. | d. Follow the prompts to label, insert and remove the diskettes. | |4.2.3. Run CHKDSK. | | The computer must be running well before you install a FixPak. If you | are experiencing any problems with your machine, please contact your | technical support representative to get the machine fixed. Even if your | machine is running well, it is a good idea to run CHKDSK; it may find | and fix some unknown problems. | | 4.2.3.1 To run CHKDSK: | | a. Shut down the computer. | b. Insert Utility Diskette 1 in drive A: and restart the computer. | c. Replace the diskettes as prompted, until you reach an A:\ prompt. | d. Insert the last utility diskette (Utility Diskette 3 for OS/2 Warp 3, | Utility Diskette 4 for OS/2 Warp 4). | e. At the A:\ prompt, type CHKDSK C: /F, then press Enter. | CHKDSK will search the disk and attempt to fix any problems. | f. If CHKDSK reports any problems, record the errors, then rerun CHKDSK | to verify that the problems were actually fixed. | |4.2.4. DO NOT USE YOUR SYSTEM | | Once you begin a FixPak installation, do not try to use your system for | any other purpose. Unexpected problems may arise, causing the FixPak | installation to fail. | |4.2.5. Record Your Current Revision Level Number. | | Before beginning the FixPak installation, verify the current version and | revision level of the operating system, as follows: | | Open an OS/2 Command Prompt window, and type VER /R, then press Enter. | Record the information displayed; for example: | | The Operating System/2 Version is 4.00 | Revision 9.030 | | Once you have completed the FixPak installation, you can verify that the | revision number has been properly updated. | | |4.2.6. UNDERSTAND ALL THE WORDS | | If there are any words, phases or instructions in this document that you | do not understand or if you do not know their meaning, please contact | your local support representative for an explanation. | | Once you have successfully completed all of the above steps, and are | satisfied that your system is in good working order and ready to begin, | proceed to the instructions below. If you have any questions or | concerns, contact you computer support adminstrator and address them | before continuing. | |4.2. Basic Installation Instructions | | There are several ways to install a FixPak; this section of the readme | uses the FPINST procedure. | | 1. Shutdown your computer. | | 2. Insert Utility Diskette 1 in the diskette drive and restart the | computer, either by turning on the power, or pressing the | Ctrl+Alt+Del keys. | | 3. As prompted, remove and insert utility diskettes until you come to an | A:\ prompt. | | 4. Remove the current utility diskette, and insert the last of the | series (Utility Diskette 3 for OS/2 Warp 3, or Utility Diskette 4 | for OS/2 Warp 4). | | 5. Type CHKDSK C: /F then press Enter. This will run the CHKDSK program. | Review the reported findings. Look for any recognizable problems and | fix them. | | Note: If CHKDSK does detect problems, run the command again, to | verify that the problems were really fixed. If CHKDSK continues to | find problems and is unable to fix them, please contact your local | support representative to resolve the problems before continuing | with the FixPak installation. | | 6. As mentioned in Section 2.1 above, CHKDSK also reports the amount of | free space remaining. If you have at least 70 MB free (70000 | Kilobytes or 70000000 Bytes) then you can proceed with the FixPak | install. If not, you must delete or move enough files to meet the | free space requirement before continuing. | | 7. Insert the Corrective Service FixTool diskette (CSF FIXT 141). | | 8. At the command prompt, enter one of the following commands and then | press Enter. | | For an OS/2 Warp 3 or Warp Server Base FixPak: | FPINST Warp3 | | For an OS/2 Warp 4 Base FixPak: | FPINST Warp4 | | 9. The FixPak installation program will perform a variety of functions. | | Note: Near the beginning of the FixPak installation, it may appear | as if nothing is happening. Please be patient. | | The only other user action required will be to remove and insert | diskettes as prompted. | | When the installation is complete, you will be informed and prompted | to restart the computer. Do this by pressing Ctrl+Alt+Del, or by | turning the power off and then back on. ****************************************************************************** Section 5. Other Ways to Apply Service Once you have boot capability (see Section 1) and are at a command prompt, you can apply service using one of the following methods: Using FPINST Using SERVICE Using FSERVICE with a custom RESPONSE.FIL Insert the FixTool diskette you created, or change to the directory that the FixTool is in, and then use FPINST or FSERVICE as described in Sections 5.1 and 5.3. To use SERVICE as described in Section 5.2, you must have OS/2 running without having booted from diskettes, maintenance partition, or via Alt-F1. 5.1. Using FPINST To use FPINST, change to the diskette or directory where you have FPINST.CMD and the related files, and type FPINST fixpak_type where fixpak_type is WARP3 for OS/2 Warp Version 3.0 FixPak installs, WARP4 for OS/2 Warp Version 4.0 FixPak installs, or NETWORK for LAN or network-related FixPak installs, and is an optional parameter that is only valid when fixpak_type is NETWORK. This is the boot drive of the system. This restricts the application of FixPaks to specific drives on systems where more than one OS/2 system is applied. | FPINST uses FSERVICE with default response files. These default response | files do the following: | | For OS/2 Base FixPaks, the default response file saves an archive copy of the | files it services in :\ARCHIVE. It does not keep a backup for | files serviced, other than the archived files. If this is not the first OS/2 | base FixPak installed and if you want to be able to backout to the previous | FixPak level, you must modify the default response file. | | Also, the default response file does not automatically replace all files from | the FixPak. The FixTool will prompt you to find out whether to replace any | files on the system that appear to be newer than the files in the FixPak. | This happens because the REPLACE_NEWER flag is not set in the default | response file for OS/2 Warp v3 or v4. | | For LAN or network-related FixPaks, there will be no archives or backups | kept by default, and the FixTool will service all partitions that contain | the product being serviced by that FixPak. If you wish to restrict the | drives serviced, you must modify the default response file. | | NOTE: If you need to install a FixPak with different options from the ones | described above, then you must either modify the default response file or | use SERVICE instead of FPINST. See Section 6 for information about how to | modify a response file. See the next section for information about SERVICE. 5.2. Using SERVICE To use SERVICE, go to the diskette or directory where you have SERVICE.EXE and the related files. Then type SERVICE The program will prompt you for required inputs. See README.INF for more information about these panels. With FixTool Version 1.39 or later, the CSFUTILPATH defaults to the path that you have executed SERVICE from, so you do not need to set this environment variable if all the FixTool files are in the same directory with SERVICE.EXE. NOTE: To use SERVICE, you must have the OS/2 PM Shell running. You cannot run SERVICE if you have booted from install diskettes or if you pressed Alt-F1 to get to a command prompt. 5.3. Using FSERVICE To use FSERVICE from a diskette, copy your customized RESPONSE.FIL to the diskette with the FixTool files, then go to the diskette and type FSERVICE /R:RESPONSE.FIL If you have copied the FixTool files into a directory, you need to use the following command from the directory with FSERVICE.EXE and the related files (including your custom RESPONSE.FIL): FSERVICE /R:RESPONSE.FIL /S::\ where is the drive with the FixTool related files and is the directory structure where you put the FixTool files. There are optional parameters that can be included on the FSERVICE command line. See the README.INF file for more details about these parameters. You should use the /B: parameter with FSERVICE when applying LAN FixPaks on systems with more than one OS/2 boot partition. is the OS/2 boot partition to be serviced. ****************************************************************************** Section 6. How to Set Up the FixTool for Remote Installation To speed up FixPak installation or to setup a FixPak on a LAN drive for use by others (Redirected Install), follow these steps. Before you begin, it is recommended that you install a Virtual Floppy Disk program such as SVDISK (Super Virtual Disk) or VFDISK (Virtual Floppy Disk). In the following examples, d: is the working drive and j: is the Virtual Floppy drive. Replace this with the drive letters you use. Also in these examples, XR_W035 is the FixPak name. First, setup a directory to hold the FixTool code. For example, run the following to place the FixTool into the d:\csf directory. | cs_141.exe d:\csf Next, setup the FixPak directory using the diskette images. loaddskf xr_w035.1dk j: /f/y/q xcopy j: d:\xr_w035\ /h/o/t/s/e/r/v loaddskf xr_w035.2dk j: /f/y/q xcopy j: d:\xr_w035\ /h/o/t/s/e/r/v ... ... ... Install the FixPak by running service.exe. set csfutilpath=d:\csf set csfcdromdir=d:\xr_w035 d: cd csf service (or start service) You can also apply service by running fservice.exe with a response file. d: cd csf fservice /r:d:\csf\response.wp3 /s:d:\xr_w035 This will apply the FixPak to all serviceable partitions. If you want to make the response file specific to a partition (drive) then you need to change the :SYSLEVEL and :ARCHIVE lines in response.wp3: :SYSLEVEL \OS2\INSTALL\SYSLEVEL.OS2 :ARCHIVE \ARCHIVE -- should be changed to -- :SYSLEVEL x:\OS2\INSTALL\SYSLEVEL.OS2 :ARCHIVE x:\ARCHIVE where x: is the drive you want serviced. ****************************************************************************** Section 7. How to Customize the Response File There are three standard response files included with the FixTool that can be modified for your configuration needs. To modify a response file, copy one of the standard response files (RESPONSE.WP3, RESPONSE.WP4, or RESPONSE.LAN) to a file called RESPONSE.FIL. Modify the RESPONSE.FIL as needed, and then run FSERVICE /R:RESPONSE.FIL. The following sections show a few of the service actions you can take through a response file. For more information about response files, view the README.INF file that comes with the FixTool. 7.1. Applying Service to a Product Without an Existing Archive This response file can be used to apply service for the first time using FSERVICE when there is no existing archive of the product being serviced. It will service all partitions and place an archive in each partition. It does not take a backup of changed files. In this case, the SERVICE.LOG file will go into the C:\OS2\INSTALL directory. Files that are read-only, hidden, or system files will be replaced automatically during service. The FixPak source files are on A:. The FixTool will service all partitions where \OS2\INSTALL\SYSLEVEL.OS2 and \MMOS2\INSTALL\SYSLEVEL.MPM are found, and it will save the original files in an \ARCHIVE directory for each partition serviced. Note that the :LOGFILE tag is optional and may be overridden by using the /L: parameter on the FSERVICE command line. The :FLAGS and :SOURCE tags are also optional, but if used, the :SERVICE tag must be included. The :SOURCE tag can be overridden by using the /S: parameter on the FSERVICE command line. You should include a :SERVICE, :SYSLEVEL, and :ARCHIVE tag for each product to be serviced. Note that the :SERVICE, :SYSLEVEL, and :ARCHIVE tags must appear in the order shown in this example. | The REPLACE_NEWER flag can be added to the :FLAGS line as shown here: | :FLAGS REPLACE_PROTECTED REPLACE_NEWER | | This flag will replace files automatically instead of giving a pop-up | panel that questions whether you want to replace a file that is newer on | the system with an older version from the FixPak. | | Warning: Using the REPLACE_NEWER flag may cause files to be back-leveled. | Be sure that you know it is okay to replace the files that are newer before | you use this flag. | | This flag was included in the previous default response files for OS/2 Warp 3, | but has been deleted because it allows you to back-level files | unintentionally. :LOGFILE C:\OS2\INSTALL\SERVICE.LOG :FLAGS REPLACE_PROTECTED :SOURCE A:\ :SERVICE :SYSLEVEL \OS2\INSTALL\SYSLEVEL.OS2 :ARCHIVE \ARCHIVE :SERVICE :SYSLEVEL \MMOS2\INSTALL\SYSLEVEL.MPM :ARCHIVE \ARCHIVEM For OS/2 Warp 4 systems, the multimedia lines are not needed in the response file. So, the last three lines in the previous example should be removed or commented out of the response file for OS/2 Warp 4.0. 7.2. Applying Service to a Product With an Existing Archive This response file can be used to apply service using FSERVICE when there is an existing archive of the product being serviced. This demonstrates the ability to take a backup of changed files. Notice that each product serviced must be backed up to a different directory, so the drive must be explicitly defined in the :SYSLEVEL, :ARCHIVE, and :BACKUP lines. Also note the order of the :SERVICE, :SYSLEVEL, :ARCHIVE, and :BACKUP tags. These tags must appear in this order. The :BACKUP tag is optional. | The REPLACE_NEWER flag can be added to the :FLAGS line as shown here: | :FLAGS REPLACE_PROTECTED REPLACE_NEWER | | This flag will replace files automatically instead of giving a pop-up | panel that questions whether you want to replace a file that is newer on | the system with an older version from the FixPak. | | Warning: Using the REPLACE_NEWER flag may cause files to be back-leveled. | Be sure that you know it is okay to replace the files that are newer before | you use this flag. | | This flag was included in the previous default response files for OS/2 Warp 3, | but has been deleted because it allows you to back-level files | unintentionally. :LOGFILE C:\OS2\INSTALL\SERVICE.LOG :FLAGS REPLACE_PROTECTED :SOURCE A:\ :SERVICE :SYSLEVEL C:\OS2\INSTALL\SYSLEVEL.OS2 :ARCHIVE C:\ARCHIVE :BACKUP C:\BACKUP :SERVICE :SYSLEVEL C:\MMOS2\INSTALL\SYSLEVEL.MPM :ARCHIVE C:\ARCHIVEM :BACKUP C:\BACKUPM For OS/2 Warp 4.0, the last four lines are not needed in the response file. 7.3. Backing Out to the Archive Level of a Product This is a sample response file to be used when backing out to the archive level of a product. Note that you can only use one :TARGET tag in the response file. Also note that the :TARGET tag must appear before a :BACKOUT tag is used. :LOGFILE C:\OS2\INSTALL\SERVICE.LOG | :SOURCE A:\ :TARGET ARCHIVE :BACKOUT :SYSLEVEL C:\OS2\INSTALL\SYSLEVEL.OS2 :BACKOUT :SYSLEVEL C:\MMOS2\INSTALL\SYSLEVEL.MPM For OS/2 Warp 4.0, you do not need to include the last two lines of this example in your response file. 7.4. Backing Out to the Backup Level of a Product This is a sample response file to be used when backing out to the backup level of a product. :LOGFILE C:\OS2\INSTALL\SERVICE.LOG | :SOURCE A:\ :TARGET BACKUP :BACKOUT :SYSLEVEL C:\OS2\INSTALL\SYSLEVEL.OS2 :BACKOUT :SYSLEVEL C:\MMOS2\INSTALL\SYSLEVEL.MPM For OS/2 Warp 4.0, you do not need to include the last two lines of this example in your response file. 7.5. Committing a Product This is a sample response file to be used when committing a product. :LOGFILE C:\OS2\INSTALL\SERVICE.LOG | :SOURCE A:\ :COMMIT :SYSLEVEL C:\OS2\INSTALL\SYSLEVEL.OS2 :COMMIT :SYSLEVEL C:\MMOS2\INSTALL\SYSLEVEL.MPM For OS/2 Warp 4.0, do not include the last two lines of this example in your response file. 7.6. Redirecting an Archive of a Product to Another Existing Archive This is a sample response file to be used when redirecting an archive of a product to another existing archive location. One example of this would be for using a shared network archive. Note that the archive directory specifies the location of an existing archive to which the current product is being redirected. In this example the arbitrary drive shows S:, which may be a LAN drive. :LOGFILE C:\OS2\INSTALL\SERVICE.LOG | :SOURCE A:\ :REDIRECT :SYSLEVEL C:\OS2\INSTALL\SYSLEVEL.OS2 :ARCHIVE S:\ARCHIVE :REDIRECT :SYSLEVEL C:\MMOS2\INSTALL\SYSLEVEL.MPM :ARCHIVE S:\ARCHIVEM For OS/2 Warp 4.0, do not include the last three lines of this example in your response file. ****************************************************************************** Section 8. How to Turn Off Archiving for a FixPak With FixTool 1.40 and later, a new utility called ARCHCTL.CMD is included. This utility allows you to turn off the archiving feature of a FixPak. This is especially useful if you have already tested a FixPak in a controlled environment and are convinced that there will be no need to backout the FixPak to an original product level. With archiving turned off, you may include a backup directory and backup to your previous level if desired. But you will not be able to back up more than one level. For example, if you install OS/2 Base FixPak 8 with archiving turned off and include a backup directory, then when you install FixPak 9, the backup directory for FixPak 8 is deleted. If you do not include a backup directory with archiving turned off, there is no way to back up to a previous level. The syntax for the ARCHCTL utility is as follows: ARCHCTL ON|OFF fixpak_source where ON|OFF indicates the action to perform. ON enables archiving; OFF disables it. fixpak_source is normally the drive with the first FixPak diskette, but it can also be the root of the FixPak when copied to the hard disk (where the \FIX subdirectory is located). The default for OS/2 FixPaks is ON. The default for LAN FixPaks is OFF. Examples for turning archiving OFF: Example 1. 1. Place first FixPak diskette in A: 2. Enter ARCHCTL OFF A: Example 2. 1. XCOPY all FixPak diskette data to N:\FIXES\FP32 2. Enter ARCHCTL OFF N:\FIXES\FP32 Examples for turning archiving ON: Example 3. 1. Place first FixPak diskette in A: 2. Enter ARCHCTL ON A: Example 4. 1. XCOPY all FixPak diskette data to N:\FIXES\FP32 2. Enter ARCHCTL ON N:\FIXES\FP32 ****************************************************************************** Section 9. Setting Environment Variables There are several SET statements that set environment variables for the FixTool to use. See the table below for a list of these variables and a description of what they do. Environment Variable Usage ------------------------------- ----------------------------------- SET CSFUTILPATH=path Allows you to run SERVICE or FSERVICE from your hard drive or from a redirected drive. SET CSFCDROMDIR=path Allows you to install a FixPak from a redirected drive or CD-ROM. All of the FixPak files should be in this path. This path should NOT be pointing to a floppy (or virtual floppy) drive. SET REMOTE_INSTALL_STATE=0|1 If this variable is set to 0, then upon termination FixTool returns control to the calling process. SET CSFDRIVEAPPLY=d Allows you to restrict service to products found only on drive d and on the boot drive. | SET CSFTIMESTAMP=1 Adds a timestamp to each line of the | SERVICE.LOG file. ****************************************************************************** Section 10. If You Have a Problem If the FixPak does not install properly, there are files you can look in to find out what error occurred. The SERVICE.LOG file is the first place to look. The FixTool puts it in the x:\OS2\INSTALL directory where x: is the OS/2 boot drive. | If the FixTool is unable to complete processing successfully, then the next | time you use the FixTool, it will try to recover, picking up from where it | stopped previously. It uses information from C:\FIXSTART to recover. You | may also notice a directory $CSFTMP$ on a drive that had the largest amount | of free space available when the FixTool last started. It is safe to delete | this directory and any files in it any time the FixTool is not running. This | directory is recreated on the drive with the most free space available | whenever starting the FixTool. Due to system usage and drive space changes, | it may not be the same drive each time for this directory. ****************************************************************************** Section 11. Common Error Messages Here are some common error messages that you may receive when running SERVICE. - Error message: An error occurred while searching for files to update. The reason may be old or corrupt CSF logfiles, CSF_SEL.000 file, or file system corruption. See README file for more information. Explanation #1: You may get this if you have used the new FixTool (version 1.38 or later) to install a FixPak, and then try to use an old version of the FixTool (version 1.37B or earlier). Solution #1: If you are installing a LAN FixPak, you can delete all the LOGF0000.xxx and LOGSTART.xxx files on your system, and reapply the FixPak. If you are installing an OS/2 FixPak, you will also need to copy your original SYSLEVEL.OS2 file back into the \OS2\INSTALL directory. Explanation #2: You may also get this error if you are trying to service a system that has many syslevel files (over about 150) on all drives. Solution #2: If your system has a large number of syslevel files, you may have to limit the search for products to be serviced by using the following set statement before you run SERVICE: SET CSFDRIVEAPPLY=d where d is the drive you wish to service. This statement limits the search for serviceable products to one drive at a time in addition to the boot drive. This will get the number of files opened down to a workable level. - Error message: No products were found on the target system to service. Explanation #1: Your SYSLEVEL.xxx file does not contain the proper prerequisite FixPak number or product information. In order to install a FixPak, the number of the FixPak must be higher than the number of the current CSD in the SYSLEVEL.xxx file, or the product information must match. Solution #1: Check the prerequisites needed for the FixPak you are trying to install. Some FixPaks have a particular FixPak that must be installed prior to installing that FixPak. Also, make sure that the FixPak you are trying to install is one that may be applied to that product. If the product information is incorrect, you may need to copy the product SYSLEVEL.xxx file from the install media. Explanation #2: If you have committed an OS/2 base FixPak with Version 1.38 or Version 1.39, you may get this message when you try to install another FixPak. Solution #2: Copy the product's SYSLEVEL.xxx file from the install media or from a backup copy that was made prior to committing the FixPak. - Error message: The path does not exist or is invalid. Explanation: FixTool could not unpack the file specified in the message, or it could not unpack the file just prior to the file specified in the message. Solution: This indicates that the FixPak media is bad. You should download the FixPak again, re-create the FixPak diskettes, and then re-install the FixPak. The FixTool will resume, starting at the point where it stopped. If you get RC=109 in the service.log, the file listed prior to the first RC=109 is probably giving an unpack error. The modules that received the 109 error were not updated properly. Make sure that you are using the UNPACK2.EXE that comes with this version of the FixTool. You should also download the FixPak again and re-create the FixPak diskettes. Then reinstall the FixPak from the new media. The FixTool will resume, updating any files that were not originally updated. If this does not fix the problem, please contact your service representative. - Error message: Error reading file \IBMCSFLK.DLL. Explanation: FixTool could not find the files needed for servicing. Solution: Make sure that you've set the CSFUTILPATH and CSFCDROMDIR environment variables if you're running service from a hard drive. The CSFUTILPATH should point to the directory that contains the FixTool files (SERVICE.EXE, FSERVICE.EXE, etc.), and CSFCDROMDIR should point to the directory that contains the FixPak files (with the FIX directory). Also make sure that all the files listed in Section 2 are in your FixTool file directory. - Error message: No source drive is available. Explanation: The FixTool first checks for removable drives on the system. If there are no removable drives, you will get this error message if you have not set the CSFCDROMDIR to point to a valid hard drive or LAN drive. Solution: Set the CSFCDROMDIR to point to the drive and directory that contain the FixPak files. - Error message: Checksum error in . Explanation: The FixTool checks the checksum of the source media with a checksum that was recorded when the FixPak was created. If these values do not match, you will receive this error. Solution: This indicates that the FixPak media is bad. Download the FixPak again and re-create the FixPak diskettes, or get another FixPak CD. Then reinstall the FixPak. The FixTool will resume, starting at the point where it stopped. - Error message: The path SET CSFCDROMDIR= does not exist or is invalid. Explanation: FixTool could not find the FIX directory in the path given in the SET CSFCDROMDIR statement. Solution: Check to make sure the path given in the SET CSFCDROMDIR statement is pointing to the directory that contains the FixPak. This directory should contain all the files and directories included in the FixPak. Here are some common error messages that you might see when running FSERVICE. - Error message: CSF257: No product has been selected. Explanation: This error message is reported in several situations. You may not have selected a product to service in the RESPONSE.FIL, or FSERVICE may not have found any products to service. If FSERVICE didn't find any products to service, either the product information on the system did not match the product information in the FixPak, or FSERVICE determined that the FixPak would back-level the system. Solution: Check the prerequisites for the FixPak and make sure that the system contains the proper pre-requisites. Also, be sure that the FixPak you are trying to install is being applied to the appropriate product. If the product information is incorrect, you may need to copy the product SYSLEVEL.xxx file from the install media. - Error message: This portion of service has completed. Reboot your system before applying additional service or using the product to process files that were locked during service. Explanation: This appears as a red screen with a title of "Corrective Service Facility Fatal Error," but the message may not indicate an error. Please view the service.log file by pressing Enter. This screen appears after doing a backout with FSERVICE so that you can check the log file to make sure there are no errors before you reboot your system. Solution: Make sure that there are no errors logged and then press Ctrl-Break to exit service. If there were no errors in the log file, then FSERVICE completed successfully and it's safe to reboot your system. - Error message: Error reading file \IBMCSFLK.DLL. Explanation: FixTool could not find the files needed for servicing. Solution: Make sure that all the files listed in Section 2 are in the directory (or on the diskette) with the FixTool files. Also, make sure your /S: parameter path is valid. It should contain the FixPak files with the FIX directory. Sometimes you may need to include the /S: parameter--even if you have set SOURCE properly in the response file. ****************************************************************************** Section 12. Other Known Problems The following problems have also been encountered: - When using SERVICE, one of the panels contains a Reboot button that no longer is needed. This button was used when you wanted to reboot from the CSF boot diskettes, but the CSF boot diskettes are no longer available. You should select Continue, or you can select Cancel and reboot the system using boot diskettes for that product. - BOOTOS2 induced problem. BOOTOS2 (corrected in latest version) copied the SYSLEVEL.OS2 file from the booted partition which was used to create the BOOTOS2 partition to the new partition. This SYSLEVEL.OS2 file could have had default service directories that included drive letters in it. Since BOOTOS2 copied the file to a different partition, the wrong drive letter would be specified for the FixTool to use when looking for files to be serviced. The SYSLEVEL.OS2 normally would have default directories in it after one had applied service to a partition, or possibly after the system install. The net result here is that if you had a SYSLEVEL.OS2 file with default directories in it, then created a BOOTOS2 partition, and later tried to service the BOOTOS2 partition, the FixTool not only would apply service to the BOOTOS2 partition, but the default directories in the SYSLEVEL.OS2 file as well (the partition where the SYSLEVEL.OS2 came from). The solution here is to copy the SYSLEVEL.OS2 from your distribution diskette or CD into OS2\INSTALL directory of the BOOTOS2 partition before applying service to that partition. | - A trap can occur if you include an unformatted drive for the archive | directory. This occurs even if you format the drive in a different | session before the FixTool processes any files for archiving. This | happens because the FixTool scans for formatted drives at the beginning | of the program and creates a list of possible drives, which is not added | to during subsequent processing. | The solution is to make sure that you have a valid, formatted drive | given for the ARCHIVE directory BEFORE the FixTool starts. If not, you | must stop and then restart the FixTool once the drive is valid. | - If your drive C: is formatted with NTFS or FAT32, you may get the following | error message: "An error occurred. The reason may be old or corrupt CSF | logfiles, CSF_SEL.000 file, or file system corruption." This is a general | error message that's returned when an unexpected return code is encountered. | The error is sent because the FixTool searches for the FIXSTART file on C:, | and therefore needs a C: partition that contains data it can read, such as | FAT or HPFS. | The solution is to create a dummy C: partition that's formatted FAT or HPFS. | Try to boot to that C: partition (which will fail, but allows it to remain | the active C: partition). Then boot OS/2 and install the FixPak. | Finally, boot to the other C: partition, which will make it the default C: | drive. ****************************************************************************** Section 13. List of Changes Made for Each Version (1.38 and Later) This section gives a description of what changes have been made for the new versions of the FixTool (Version 1.38 and later). | NOTE: FixTool 1.41 and FixTool 1.37B are the only supported FixTools. | FixTool 1.41 supersedes all FixTools. FixTool 1.37B can | continue to be used only on FixPaks that it was released with. | All other FixPaks should use FixTool 1.41. | Changes Made in Version 1.41 | | - Added the ability to include a timestamp in the SERVICE.LOG file. | | - Enhanced the performance when installing from diskettes. | | - Copy packed files to a temporary directory on the hard drive and then | run checksum and unpack against the files on the temporary directory. | An additional 1.1 MB is required for this processing. The drive used for | this is the one with the most available space. | | - Fixed error that occurred when C: is the CD-ROM drive. CSF_SEL.000 and | FIXSTART will be written to the first non-removable, non-network drive | on the system. | | - Changed Backout routine so that any CSBKExxx.EXE exit routines will run | last, after the syslevel files are updated and the files are backed out. | | - Updated FILEFIX.DLL to detect invalid release numbers. These must be | between 1 and 255. Also, this file was updated to not return a mismatch | when the file versions are the same. Changes Made in Version 1.40 - Fixes a commit problem introduced with FixTool 1.38. If you committed an OS/2 base FixPak with Version 1.38 or 1.39, you cannot install subsequent FixPaks without reverting to a SYSLEVEL.OS2 file used prior to the commit (you can use the SYSLEVEL.OS2 that was shipped with the product from the product diskettes/CD). After you had done a commit, applied a FP to the committed base, and then either restored from the commit Archive or backed out an installed FP, the fact that the base was at a specific FixPak level was lost. The FixTool will now create in OS2\INSTALL a file named FPCOMMIT.OS2 to hold the base committed SYSLEVEL. This will be restored to SYSLEVEL.OS2 during either of these 2 restore activities. Do not erase this file. - Eliminates a SYS0039 error when using SERVICE without a diskette in the drive when starting the FixTool. - Allows you to set a new CSFDRIVEAPPLY environment variable prior to running SERVICE which will limit the search for products to be serviced to the drive given in the set statement and to the boot drive. - Includes an updated FPINST.CMD file that uses the /B: parameter for LAN-related FixPak installations. - Includes an updated UNPACK2.EXE and updated error handling for messages coming from UNPACK2.EXE. - Includes checksum verification on the source media. This fix prevents corrupted source files from being transferred to the target system. You may also notice a slight increase in the time it takes to process files to be updated. - Includes an ARCHCTL utility that allows you to turn off archive processing for a particular FixPak. Changes Made in Version 1.39 - Works with OS/2 Warp v3.0 and LAN-related FixPaks. The backout- to-backup process was fixed for LAN-related FixPaks. - The CSFUTILPATH environment variable does not have to be set to be able to run SERVICE from a hard drive. - Now services systems that do not have a removable media drive. - Contains an updated response file for Warp 4 systems. Changes Made in Version 1.38 NOTE: Version 1.38 of the FixTool was for use with OS/2 Warp v4.0 systems only. - Updates the CSD level in the SYSLEVEL.xxx file for all products. The CSD level is updated to match the FixPak number. - Recognizes Software Choice installed features. When backing out a FixPak, you will be given a chance to cancel the backout if a Software Choice installed feature will be broken by the FixPak backout. - No longer uses CSF boot diskettes. The FixTool now comes as a self-extracting zip file that can be unzipped to a single diskette. - Places the locked file device driver statements closer to the beginning of the CONFIG.SYS. - Corrects a problem with the backout-to-backup process when a file is serviced in more than one directory.