| Symptom / Error | FRU / Action | 
| 0001 01XX Interrupt failure.
 Possibly a bad battery or processor
 | 1. Run Advanced Diagnostics 2. 486DX33 Upgrade (70/80)
 | 
 
| 0001 02XX ROM checksum or timer error.
 Possibly a bad battery or processor
 | 1. Run Advanced Diagnostics 2. 486DX33 Upgrade (70/80)
 | 
 
| (If the battery was removed while replacing the 80386 processor in a model 70, with a 486DX33 Processor Upgrade (FRU Number  92F0436), remove the 486DX33 processor and install the 80386 processor, then install the battery. Configure the system and re-install the 486DX33 processor without removing the battery.)
 |  | 
| 0001 0300 Checksum or timer error.
 If it is a 20 MHz board, and the processor is not a 487SX, the jumper must be in positions 2 and 3
 (487SX is indicated on the processor)
 | 1. Processor Board (90/95) 2. System Board
 | 
| 0001 02XX 0001 03XX
 0001 04XX
 0001 07XX
 | 1. System Board 2. Processor Board
 | 
| 0001 05XX Command not accepted
 | Information only | 
| 0001 06XX Converting logic test failure
 | 1. Run Advanced Diagnostics | 
| 0001 07XX / 0001 08XX 0001 09XX
 Interrupt or memory failure
 | 1. System Board Memory 2. System Board
 3. Processor Board (90/95)
 4. Any Adapter
 5. Bus Adapter
 | 
| 0001 0XXX any other not listed
 | 1. System Board | 
| 0001 10XX Check Memory
 (For Model 56 / 57 & 90 / 95, also
 see 000201XY for socket location list)
 | 1. Memory Module Kit 2. System Board
 | 
| 0001 11XX I/O channel check
 | 1. Adapter Memory 2. Expansion Adapter
 3. System Board
 | 
| 0001 12XX  / 0001 13XX Possible MC-timeout error
 Often caused by a card with defective MCA bus interface or too slow responding card.
 | 1. System Board 2. Processor Board (90/95)
 3. Any Adapter
 | 
| 0001 14XX ROM error
 | 1. Any Adapter 2. Bus Adapter
 | 
| 0001 15XX 80386 protected mode failure, or BIOS
 checksum error
 | 1. System Board 2. 486DX33 Upgrade (70/80)
 | 
                                                                  
| 0001 16XX Possible read/write problem
 | 1. Run Advanced Diagnostics 2. 486DX33 Upgrade (70/80)
 | 
| 0001 18XX Previously detected error.
 Run Advanced Diagnostics
 | 1. System Board Memory 2. Processor Board (90/95)
 | 
| 0001 19XX 2.88MB diskette drive is
 installed but not supported.
 | 1. Run Automatic Configuration 2. System Board
 | 
| 0001 1XXX not listed above
 | 1. System Board | 
                                                                  
| 0001 20XX Possible Processor self test failure
 (90/95)
 | 1. System Board Processor Cache 2. Processor Board (90/95)
 | 
| 0001 21XX A problem was detected during
 memory remapping (256KB ROM Error)
 | Information only | 
| 0001 22XX POST found a hardware error
 | 1. Run Advanced Diagnostics | 
| 0001 2201 / 0001 2202 0001 2203 / 0001 2204
 0001 2205 / 0001 2206
 0001 2207 / 0001 2208
 Data error, Possible system board failure
 | 1. Run Advanced Diagnostics | 
| 0001 29XX | 1. Run Advanced Diagnostics 2. Cache Kit
 3. System Board
 | 
| 0001 30XX POST could not start the operating system. Operating system loaded ?
 Is the boot drive in the selectable drive sequence ?
 | 1. Check Drive Sequence | 
| 0001 3001 Security system is being used, but the computer is not totally secured because there is a diskette drive in the startup sequence
 | 1. Delete diskette drive from the startup sequence if so desired. | 
| 0001 3002 Drive startup sequence is corrupt
 or invalid
 | 1. Run Automatic Configuration, then reset the selectable drive startup sequence. If the problem still exists, replace the system board | 
| 0001 3003 EEPROM could not be read
 | 1. Run Automatic Configuration If the problem still exits, replace the system board.
 | 
| 0001 31XX | 1. System Board | 
| 0001 32XX DMA extended registers error
 | 1. Run Advanced Diagnostics | 
| 0001 33XX DMA verify function error. Logic failed
 | 1. Run Advanced Diagnostics | 
| 0001 34XX DMA arbitration logic error
 | 1. Run Advanced Diagnostics | 
| 0001 4905 | 1. System Board 2. Processor Board
 | 
| 0001 4908 / 0001 4909 Before replacing any FRUs, see 'Cover Lock and Tamper-Evident Switches'
 | 1. System Board 2. Tamper Evident Switches
 3. Keylock Assembly
 | 
| 0001 52XX Real time clock error.
 This is not always a hardware failure. See also 'Real-Time Clock Problems'
 | 1. Run Advanced Diagnostics | 
| 0001 56XX Security error.
 The covers were removed without using the key. The tamper evident switch was tripped.
 | 1. Start the system from the Reference diskette (or server image) and reconfigure the system. 2. Security Switch Assembly
 3. System Board
 |