* COMPONENT_NAME: IBM C and C++ Compilers, Version 3.6.5, Fixpak 2
*
* FUNCTIONS: README for Windows NT
*
* (C) COPYRIGHT International Business Machines Corp. 1994,1998,2000
*
* All Rights Reserved.
* Licensed Materials - Property of IBM
*
* US Government Users Restricted Rights - Use, duplication or
* disclosure restricted by GSA ADP Schedule Contract with IBM Corp.
**********************************************************************

Installation
-------------

To install this Fixpak perform the following steps :

(1) Reboot your machine.

(2) Unzip the Fixpak into a temporary directory. The unzipped Fixpak 
    occupies about 78M bytes.

(3) Make sure you are currently in the directory into which the fixpak
    was unzipped.

(4) Issue the following command :

      SETUP

(5) Follow the instructions carefully. This Fixpak uninstalls the old
    product before installing itself.

(6) Reboot the machine.  


IMPORTANT INFORMATION
---------------------
This file contains important information about the IBM C and C++
Compilers product.  You should read the following notes before you
install and use this product. The second part of this file contains
additional configuration for the html help system and search facility.


1. Debugger
-----------

   o  The Debugger that is shipped in the product is not supported on
      Windows 2000. Use IBM Distributed Debugger V8.5 instead.

   o  Closing the process list dialog with Alt-F4 will cause the
      debugger to crash.  The process list dialog must be closed by
      clicking the Cancel button.


   Installing the Remote Debugger (Windows 95, Windows 98)
   -------------------------------------------------------
   Only remote debugging is supported for Windows 95 and Windows 98.
   You cannot debug programs running on Windows 95 or Windows 98
   locally.

   In order to debug a program on a remote Windows 95 or a remote
   Windows 98 machine, you must install the remote debugger manually
   by copying files onto the remote machine. You can only copy files
   from a Windows NT installation of the IBM C and C++ Compilers.

   To install the remote debugger on your Windows 95 or Windows 98
   machine:

   1. Choose a directory in your PATH environment variable to install
      the remote debugger files into. You can create a new directory
      (for example, C:\remdbg) and add the directory to your PATH 
      environment variable.

   2. Create an "msg" directory in your remote debugger directory (for 
      example, C:\remdbg\msg).

   3. Copy the following files from your IBM C and C++ Compilers "bin"
      directory (for example, C:\ibmcxxw\bin) to your remote debugger
      directory:

	CPPYB35I.DLL
	CPPYM35I.DLL
	CPPYU35I.DLL
	CPPDUNF1.DLL
	CPPDDLE1.DLL
	CPPDXCX1.DLL
	CPPDTCP1.DLL
	DEMANGLI.DLL
	CPPDFSRV.EXE
	IRMTDBG.EXE

   4. Copy ONE of the following language specific files from your IBM
      C and C++ compilers "bin" directory to your remote debugger
      directory:

	+-------------------------------------+
	| Language              | File Name    |
	+----------------------+--------------+
	| Simplified Chinese    | CPPDMGC1.DLL |
	| Japanese              | CPPDMGJ1.DLL |
	| All other languages   | CPPDMG1.DLL  |
	+----------------------+--------------+

   5. Copy the CPPDCC1.CAT file from your IBM C and C++ Compilers "msg"
      directory (for example, C:\ibmcxxw\msg) to your remote debugger
      "msg" directory.

   6. Set the NLSPATH environment variable on your remote machine with
      the following command:

      set NLSPATH=full_path_of_debugger_directory\cat_file_directory\%N

      For example, if your remote debugger directory is C:\remdbg, and
      your message catalogue file (.cat) is in \msg, enter the
      following command:

      set NLSPATH=C:\remdbg\msg\%N


   You can now start to debug the program on the remote Windows 95 or
   remote Windows 98 machine by following the instructions on the
   "Start the Debugger and the Remote Program" page of the online
   help.


2. Compiler
-----------

   a) The default setting for the /qarch option, which specifies the
      architecture on which the executable program will be run, has
      been changed from /qarch=x86 (any 32-bit x86 architecture) to
      /qarch=486 (any architecture supporting the 486 instruction
      set).

   b) The default setting for the /Gi option (generate fast integer
      code) has been changed from /Gi- to /Gi+.

   c) If the /Op- option (disable stack pointer optimizations) was
      being used to force the stack to be chained, note that a new
      option (/Oq) has been added that specifically controls stack
      chaining.  Using /Op+ /Oq+ when the stack must be chained will
      produce better code than using /Op-.


3. Linker/Librarian
-------------------

   a) IBM VisualAge C++ Professional, v4.0 allows function and symbol
      names of up to 64000 characters long. The ILink and ILIB
      utilities have been enhanced in IBM C and C++ Compilers V3.6.4
      to handle objects and libraries with these long names.

   b) The linker will only handle one resource file (.res) at a time.
      An error message will be issued if a user tries to link two or
      more resource files for an  application.

   c) Due to system limitation, Windows 95 users cannot specify a base
      address of lower than 0x400000 when they generate an executable.
      If /base:0xADDRESS option is used (where ADDRESS < 0x400000),
      the linker option /NOFIXed should also be used. It will allow
      the system to relocate the application as the specified base
      address is not available.

   d) When linking  a dll created  by this product with a dll created
      by another compiler and using a single icc command, such as the
      example below where "ibm.obj" is the source object of "ibm.dll"
      and "microsoft.lib" is the import library of the
      "microsoft.dll".

      icc /ge- ibm.obj microsoft.lib

   The following error message may be returned:

   "Fatal error : invalid object 'microsoft.dll' at offset xxxx xxxx"

    The following workarounds may be used to avoid the problem:
      i.   Add the linker flag of "/B" in front of any Microsoft
	   import library.  Thus icc will only pass those libraries to
	   ilink,
      ii.  Provide an export object file for linking a dll. In this
	   case, icc will not call ilib for generating xxx.exp file,
      iii. Use ilink to link the xxx.dll instead of icc.

  e) When linking a dll, we recommend the users to use the linker
     option /base:0x1000000. Without using this option to specify an
     address above the default value of 0x400000, in some situation,
     Windows 98 may have problem reloading the dll to some other
     address. Using different base addresses for different dlls may
     also reduce overhead of loader execution time.

  f) If an import library, generated by Microsoft Visual C++ V6.0 or
     later, is provided as part of an icc command to generate a dll,
     an a.exp file must be supplied.
     For example:

      icc /ge- a.c ADVAPI32.lib

     where ADVAPI32.lib is generated by Microsoft Visual C++ V6.0. The
     following error message may be returned:

      fatal error : Invalid object "ADVAPI32.dll" at offset 69237

     Since icc is needed  to call ilib to generate an a.exp file for
     the linker.

     There are two ways to workaround the problem:

     1) Append a "/B"  in front of the library name, to instruct icc
	to pass the library to the linker (ilink.exe) only. i.e.
	 
	 icc /ge- a.c /B"ADVAPI32.lib"

     2) Provide icc with an ilib.exe generated a.exp file. i.e.

	 icc /ge- a.c a.exp ADVAPI32.lib



4. C++ Run-time Libraries
-------------------------

   a) The iostream library that was part of IBM C and C++ Compilers 
      3.6.0 was not compatible with earlier products such as VisualAge
      for C++ 3.5. This has now been fixed.


5. IBM Open Class Libraries
---------------------------

   a) Motif:

      This release of the Open Class Library now contains Motif 
      support for IToolBar, IToolBarButton, ICustomButton, and the
      other related toolbar and custom button classes.


   b) Source Files:

      Please note that the Open Class source files are provided for
      reference and debugging use only.  It is not currently possible
      to regenerate the Open Class libraries from these sources and
      the compiler provided with this release.


   c) DLLs

      You can improve first-time application start-up time by
      preloading the Open Class DLLs as follows:

	  i)  Create a program object for the Hello1 IOC sample
	      (...\samples\iclui\hello1\hello1.exe)

	  ii) Put the program object into the system's startup folder

      If the program object is configured to "start minimized", the
      sample window will not display when the system is started.


   d) Notification IDs in ilistcvw.hpp and icombovw.hpp moved:

      The following notification ids have been moved:
       - From ilistcvw.hpp to ilistbas.hpp:
	     ICollectionViewListBox<Element,Collection>
		 itemChangedId,
		 itemsId,
		 extendedSelectChangedId;
	     to IBaseListBox

       - From icombovw.hpp to icombobs.hpp:
	     ICollectionViewComboBox<Element,Collection>
		 itemChangedId
		 itemsId
	     to IBaseComboBox

      They have been moved because there are problems with
      notification ids residing within template classes (static data
      members have problems with templates because with templates
      there could be multiple instances of the data member throughout
      the application). They have been moved to the base classes so
      that there will only be one instance of the notification ids in
      the application.  However these notifications are not sent by
      the base class, only by the collection listbox and combobox
      classes.  Do not use these notifications except when using the
      collection listbox or combobox.


   e) Bidirectional Support with IBM Open Class Libraries

      Conflicts in the bidirectional support provided by Open Class
      and the operating system result in the following limitations:

	o  Controls created with the pmCompatible style of the  
	   IContainerControl, INotebook, IProgressIndicator, and
	   IBaseSpinButton classes are not bidi-enabled.

	o  Other IContainerControl windows show limited right-to-left
	   behavior. For example, columns in details view will not
	   appear right-to-left and icons will not be grouped from
	   right to left.

	o  Other INotebook windows show limited right-to-left
	   behavior.  For example, tabs will not appear from right to
	   left.

	o  Help windows displayed by IHelpWindow objects created with
	   the IHelpWindow::ipfCompatible style are not bidi-enabled.

	o  Other help windows show limited right-to-left behavior.

	o  ICircularSlider is not bidi enabled.

	Additional information regarding support of bidirectional
	languages in the IBM Open Class Library can be found on the
	support page of the VisualAge C++ web site.


   f)  To optimize the IString+= operation, the IBuffer/IDBCSBuffer
       class now allocates memory in 32 bytes chunk(s). To turn this
       optimization off, you can set the static boolean
       IBuffer::is32BytesAligned to false. By default, if
       IBuffer::setDefaultBuffer()is called, the boolean is set to
       false unconditionally.


   g)  Changes/Clarifications for Windows 2000

       IFileDialog
       The file dialog has a different appearance under Windows 2000,
       displaying a tool bar on the left edge of the window. Users can
       use this tool bar to quickly select common save areas as
       presented by the operating system.

       For Windows 2000, the default work directory for the open/save
       dialog is specified by the CSIDL_PERSONAL folder path as
       returned by the SHGetFolderPath API. The CSIDL_PERSONAL folder
       path translates to the file system directory that serves as a
       common repository for documents for the current user. Thus, if
       you do not specify an initial path to IFileDialog, the default
       directory used by the dialog is the CSIDL_PERSONAL folder path.

       Applications that need access to other Windows folders should
       query the operating system for the correct path and pass it to
       IFileDialog::Settings::setInitialDrive.


       IFileDialog::Settings::setInitialDrive
       If you do not call this function and you are running on Windows
       2000, IFileDialog uses the CSIDL_PERSONAL folder path as the
       initial drive. The CSIDL_PERSONAL folder path translates to the
       file system directory that serves as a common repository for
       documents for the current user.


       IProfile changes
       The following constructor has been added to this class:

	  public:
	    IProfile( const char* profileName,
		      EType type,
		      EAccess access )

       This is supported on Windows only.

       Constructs an IProfile object that creates or opens a system or
       user profile with read-only or read/write permission, depending
       on the value of the EType and EAccess values passed to the
       constructor.

       This constructor is useful for opening or creating a user
       profile. On Windows, the constructor that takes only a profile
       name will open a system profile with read/write access. Note
       that on the Windows 2000, only an administrator can open system
       profiles with read/write permission.

	  profileName
	    Name of the profile to open or create.
	  type
	    Specifies whether the profile is a user or system profile.
	  access
	    Specifies whether the profile should be opened with
	    read-only access or created/opened with read/write access.

       Exceptions
	 IInvalidParameter
	   The IProfile object was not constructed. The profile name
	   is missing.
	 IAccessError
	   The IProfile object was not constructed. The profile name
	   may be invalid or the user is not authorized to create or
	   open the specified type of profile.

       The following enumerations have been added:

	 EAccess
	   enum EAccess { kReadOnly,
			  kReadWrite }

	   This is supported on Windows only.

	   Use this enumeration to specify the access mode for a
	   profile.

	   kReadOnly
	     Open the profile with read only permission if it exists.
	   kReadWrite
	     Create or open the profile with read and write permission.

	 EType
	   enum EType { kSystem,
			kUser }

	   This is supported on Windows only.

	   Use this enumeration to specify the profile type.

	   kSystem
	     Create or open the profile under
	     HKEY_LOCAL_MACHINE\Software in the Windows registry. Note
	     that on Windows 2000, only a user with administrator
	     permissions can do this.
	   kUser
	     Create or open the profile under
	     HKEY_CURRENT_USER\Software in the Windows registry.


       IWindow::setFocus
       This function does not change the foreground window on Windows
       2000 if another application is in the foreground. In this case,
       the other application will continue to receive keyboard input. 


       System Objects
	 Windows Terminal Server programs have two name spaces
	 available for system objects: the session name space and the
	 global name space. The IOC classes ISharedResource and
	 ISharedCondition both create system objects. You can
	 explicitly specify whether these classes should create their
	 system objects in the global or session name space through
	 the names you pass to their constructors.

       To specify a name space, add a "Global\" or "Local\" prefix to
       the name you pass when constructing an ISharedResource or
       ISharedCondition object. A prefix of "Global\" causes the
       system object to be created in the global name space. A prefix
       of "Local\" cause the object to be created in the session name
       space.

       On Windows 2000 systems without Terminal Services running, the
       "Global\" and "Local\" prefixes are ignored.

	  For example:
	    ISharedCondition("Global\\keyName")
		will create the name in global name space.

	    ISharedCondition("Local\\keyName")  
		will create the name in session name space.

	    ISharedCondition("keyName")                 
		will create the name in session which is the default.


   h)  Changes/Clarifications Regarding the Windows SDK

       Changes to support compiling with STRICT
       The Windows SDK supports stronger type checking for its handle
       types, such as HWND, HICON, and HDC, so that the compiler will
       not treat them as interchangable equivalents to void*. The SDK
       provides this stronger type checking when the STRICT macro is 
       defined at compile time. Without the stronger type checking,
       you can pass an HWND value to an API that requires an HICON.

       In the previous version of the SDK, NO_STRICT was defined by
       default. IBM Open Class Library did not support compiling with
       STRICT defined with the previous SDK.

       In the updated SDK, STRICT is now the default. Simply by
       recompiling, you will get stronger type checking on code that
       uses the SDK handle types directly, such as application code
       that calls Windows APIs that take or return SDK handle types.
       The stronger type checking in the SDK handle types could
       identify errors in code that used to compile cleanly. If you
       encounter new handle-related compiler errors, you should either
       correct the code causing the errors, or change your builds to
       define the NO_STRICT macro at compile time.

       The handle classes in IBM Open Class Library have been enhanced
       to support compiling applications with either STRICT or
       NO_STRICT defined, through the addition of new Windows-only
       constructors and operators. In order to avoid introducing
       excessive compiler errors to existing code, however, the IOC
       handle class do not enforce stronger type checking when STRICT
       is defined.

       If you want stronger type checking in the IOC handle classes,
       similar to the stronger type checking you can get in the SDK
       handle types, you should ompile your application code with
       IC_WIN_STRICT_HANDLES defined and without NO_STRICT defined.
       This stronger type checking allows you to construct an
       IWindowHandle object only from an HWND value, and not an HDC or 
       even a void* value.


       IFont
       The COM IFont class in the SDK file ocidl.h can conflict with
       the IFont class provided by IBM Open Class Library in
       ifont.hpp.  This conflict existed in the previous SDK, but is
       more likely with the updated SDK because many more SDK header
       files now include ocidl.h. To avoid a conflict, IBM has
       redefined the COM IFont class to __IWinFont. If you have code
       that uses the COM IFont class, you must do one of the following
       to refer to that version of the IFont class instead of the
       version in IBM Open Class Library:

	 - Define the macro __WIN_IFONT__ at compile time, or
	 - Replace all occurences of IFont in your code (references to
	   the COM version of IFont) with __IWinFont

       Note that you can use the COM IFont and IOC IFont classes in
       the same compilation unit only by using __IWinFont to reference
       the COM class.


   i)  Other Changes or Clarifications

       IGImage file support
       The tasks and concepts section of the online reference
       incorrectly states that the IGImage class supports PCX and TIFF
       files.


       Deletion of IThreadFn objects IBM Open Class now deletes
       IThreadFn objects when the threads running those function
       objects complete, to match behavior in previous versions of
       IOC. Before this fix, IOC was incorrectly leaking IThreadFn
       objects.

       Note that with this fix, incorrectly coded applications may 
       fail in the following cases:
	 - The application deletes an IThreadFn object that IOC has
	   already deleted or will delete.
	 - The application creates IThreadFn objects on the stack
	   instead of via operator new.
	 - The application starts another thread using an IThreadFn
	   object that IOC has already deleted.


       Deletion of IWindow attributes
       The pointer returned by IWindow::addOrReplaceAttribute is no
       longer valid after the IWindow object is deleted, or after the
       attribute is replaced by another call to
       IWindow::addOrReplaceAttribute.


6. Installing Additional Components
-----------------------------------

To install additional components follow these steps:

   1. Insert the IBM C and C++ Compilers, Version 3.6 CD-ROM into the
      CD-ROM  drive.
   2. If Autoplay is not enabled, open the CD-ROM and invoke setup.exe
   3. Choose IBM C and C++ Compilers, Version 3.6 and proceed to the
      feature selection panel.
   4. Select the new features you wish to add to your original. The
      Windows installation program does remember which features have
      originally been installed.
   5. Ensure that you select the same target drives and directories as
      you did in the original installation.
   6. Follow the remaining instructions to complete the installation.


DBCS (Double Byte Character String) NOTES
-----------------------------------------

   o  When using the English version of VisualAge C++ on a DBCS
      language environment, you need to change the LANG environment
      variable in SETENV.CMD manually. (If you don't make this change,
      you may not build DBCS application correctly, because the
      compiler assumes an English environment.)

   o  To access Graphic Data type via UDB ODBC driver, we need to set
      PATCH1  and PATCH2 in db2cli.ini. See the detailed information
      at:
	http://www.software.ibm.com/data/db2/java/dbcsjava.html


======================================================================

Part 2.                Help System Search Server

======================================================================

1.0 Searching HTML Help
-----------------------
   The search system consists of a search engine and a search server.
   The search system is stored in its own directory because it may be
   used by other products.


2.0 Using the HTML Search System
--------------------------------
   2.1 Browser requirements

       IBM HTML help requires a frames-supporting browser such as
       Netscape version 3.01 or Internet Explorer version 3.02.

       The browser that you use must not have proxy handling for the
       localhost port.  Ensure you turn off proxy handling for
       localhost in the browser you use.


   2.2 Starting and Stopping the Server

       If the search server has stopped (or you have stopped it with
       Task  Manager), you can restart it by double clicking the "Help
       Home  Page" icon in the Start menu...product folder.


   2.3 Searching with Proxies enabled in Netscape or Internet Explorer

       If you use Netscape or Internet Explorer with proxies enabled
       manually, you can speed up search significantly by modifying
       your proxy information.

       In Netscape 3:
       ----------------
       a) Select Options... Network Preferences...
       b) Click the Proxies tab
       c) Click View at the Manual Proxy Configuration selection
       d) Type:

	     localhost:49213

	  in the "No proxies for" box. If you have other entries here,
	  separate the new entry with a comma.
	e) Click OK, then click OK to exit the Proxies tab.


       In Netscape 4 (Communicator)
       ----------------------------
       a) Select Edit... Preferences..
       b) Double-click Advanced in the Category tree
       c) Click Proxies in the Advanced subtree
       d) Click View at the Manual Proxy Configuration selection
       e) Type:

	     localhost:49213

	  in the "Exceptions... Do not use proxy servers for domains
	  beginning with" box. If you have other entries here,
	  separate the new entry with a comma.
       f) Click OK, then click OK to exit the Preferences Window.


       In Internet Explorer 3 and 4
       ----------------------------
       a) Select View... Options
       b) Select Connection
       c) Type:

	     localhost:49213

	  in the "Exceptions... Do not use proxy servers for addresses
	  beginning  with" box. If you have other entries here,
	  separate the new entry with a comma.
       d) Select the "Do not use proxy server for local (intranet)
	  addresses" box
       e) Click OK

       Internet Explorer 4.0 HTTP 1.1 settings
       -------------------------------------------
       Currently the default settings on Internet Explorer cause a
       conflict with the search server.  As a workaround, disable the
       HTTP 1.1 settings checkbox from Internet Explorer's advanced
       options. Reboot of your system enable the new setting.

       Socks servers and proxies:
       --------------------------
       If you are using Netscape 3, and you dial-in to a secure site
       to access the internet with a proxy or socks server, you will
       need to delete these settings in Netscape before you can
       search. This is a bug with Netscape 3.
       Netscape Communicator simply needs to uncheck the setting to
       work properly.


3.0 If the Search System is not Uninstalled on Windows
------------------------------------------------------

   If the search system does not get uninstalled on Windows NT, the
   cause may be:

   a) Another product is using the search system runtime, so it
      cannot be removed
   b) The search system uninstall did not perform as expected

   To check whether the search system is used by other products, run
   the following command:

      nqcounti <search system's directory>.

   To find out where the search system is installed, echo the
   environment variable IMNINSTSRV.  For example, if the search system
   is installed on D:\IMNNQ_NT under Windows NT, then invoke:

      nqcounti D:\IMNNQ_NT.

   The command will return the number of indices (ie. products) that
   are still  registered  with the search engine runtime.  If the
   returns says 1 or more indices are still active, then search system
   cannot be removed as other products are still registered. If the
   search system returns '0 indices active', then the uninstall
   failed.


   3.1 Rebooting After Uninstalling the Product

       After an IBM for C and C++ uninstall, it is very important to
       reboot before doing another install. The reason is that some
       search system runtime DLLs can be held by the operating system
       and so would not be removed until the next reboot.  If a search
       system runtime install happens before the reboot, the newly
       installed search system runtime DLLs will be deleted on the
       next reboot rendering the search system runtime unuseable.


  3.2
     On Windows 2000, using Netscape to do a Help Search is very slow.

4.0 Other Changes
-----------------

    This version uses a new version of the Microsoft SDK.
    Consequently the tools supported are different.


  Win32 SDK Online Help:
    Please see "Platform SDK Documentation" of "Microsoft Platform
    SDK" for online help.